fieldcommunicator

MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors

MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived




 


Features of MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
MTL SD range 
Ultra-slim user-friendly devices for protecting electronic equipment and systems against surges on signal and I/O cabling
 
• Range of ATEX Certified intrinsically safe surge protectors
• Ultra-slim space-saving design;easy installation
• Multistage hybrid protection circuitry – 20kA maximum surge current
• Range of voltage ratings – to suit all process I/O applications
• High bandwidth, low resistance, RTD, PSTN and 3-wire transmitter versions available
• 10 year product warranty
 
Overview of MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
The SD range is a series of surge protection devices combine unparalleled packing densities, application versatility, proven reliable hybrid circuitry, simple installation and optional ‘loop disconnect’ facilities – features which make the range the ultimate surge protection solution for process equipment, I/O systems and communications networks.
 
The exceptionally high packing densities are the consequence of an ultra slim ‘footprint’ for individual modules which can thus‘double-up’ as feedback terminals. Each module provides full hybrid surge protection for 2 and 3 wire loop protection.
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Modules with a comprehensive range of voltage ratings cover all process related signals such as RTDs, THCs, 4 to 20mA loops, telemetry outstations, shut-down systems and fire and gas detectors.
 
Optional ‘loop disconnect’, is a feature which allows commissioning and maintenance to be carried out without removal of the surge protection device. This facility is provided by the SD07, SD16, SD32 and SD55 units. In addition, a third connection on the field and safe side of the protector is provided in order to terminate screens safely
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
For three wire applications the specially designed SDRTD (Resistance Temperature Detector) and the SD32T3, (for separately powered 4-20mA loops) provide full 3-wire protection in a single compact unit. The recommended choice for the protection of 3-wire pressure transducers on low power circuits is the SD07R3.
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
For higher bandwidth applications, the SDR range has been developed to meet the demands of today’s highest speed communication systems.
 
120V and 240V AC versions are available for I/O and power supplies up to three Amps of load current and telephone networks can be protected by the SDPSTN.
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
One simple manual operation clamps modules securely onto DIN rail, which automatically provides the essential high-integrity earth connection.
 
‘Top-hat’ (T-section) DIN rail is generally suitable for mounting SD modules although for adverse environments, a specially-plated version is available. A comprehensive range of mounting and earthing accessories can also be supplied. 
 
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Analogue inputs (high-level)
2-wire transmitters, 4-20mA, conventional and smart
 
The SPDs recommended for use with‘conventional’ and ‘smart’ 4-20mA transmitters (fed by a well-regulated supply) are the SD32 and SD55, the choice depending upon the maximum working voltage of the system (32V and 55V respectively). The diagram illustrates a prime example of an application for which the fuse/disconnect facility is particularly useful, however, both models are available in ‘X’ versions without the optional fuse/disconnect feature.
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Analogue inputs (low-level)
RTDs
These applications are best served using the SDRTD. For optimum accuracy, the energising current should be chosen to ensure the voltage across the RTD does not exceed 1V over the full measurement range. When using a PT100 device, we recommend an energising current of 1mA.
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Photocells, THCs, mV sources and turbine flowmeters
The SD07 or SD16 (depending upon the operational voltage) are the favoured choices for this application. SD07X and SD16X are also suitable.
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Analogue outputs
Controller outputs (I/P converters)
For this application, the recommendations are the SD16, SD32 and SD55 (and the equivalent‘X’ versions), the final choice depending upon the operating voltage.
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Digital (on/off) inputs
Switches
Suitable SPDs for switches include the SD07, SD16, SD32 and SD55 modules – the choice depending upon the operating voltage of the system. The ‘X’ versions of these are also suitable.
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Digital (on/off) outputsAlarms, LEDs, solenoid valves, etc
Alarms, LEDs, solenoid valves, etc
The recommended choice for this application is the SD32 or SD32X.
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Telemetry (PSTN)
Telemetry outstations
The SDPSTN has been designed specifically for the protection of signals transmitted on public switched telephone networks.
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
AC supplied equipment
PLC, I/O systems
For systems on 110-120V ac, the SD150X is the recommended choice and for 220-240V ac systems, the SD275X is recommended.
 
 
Technical Specification of MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
All figures typical at 77°F (25°C) unless
otherwise stated
Protection
Full hybrid line to line
Each line to screen/ground
 
Max discharge surge current (Imax) (8/20µs)
20kA (8/20µs)
6.5kA (SD150X and SD275X only)
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Nominal discharge surge current (isn)  3kA (8/20µs)
Lightning impulse current (Iimp) (10/350µs)
2.8kA
1.0kA (SD150X and SD275X only)
 
Response time  <1ns
RTD resistance range (SDRTD) 10 to 1500
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Degradation accuracy (SDRTD at 1mA)
0.1% (RTD resistance > 100 )
0.1W (RTD resistance < 100 )
Ambient temperature
–40°C to +80°C / -40°F to 176°F storage
–40°C to +80°C / -40°F to 176°F working
For IS working applications:
Pi = 1.0W (–30°C to +75°C / -22°F to 167°F)
Pi = 1.2W (–30°C to +60°C / -22°F to 140°F)
Pi = 1.3W (–30°C to +40°C / -22°F to 104°F)
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Humidity  5 to 95% RH (non-condensing)
Category tested A2, B2, C1, C2, C3
Overstressed fault mode in=3kA
12kA
9kA (SD150X and SD275X only)
Impulse durability (8/20µs)
10kA
6.5kA (SD150X and SD275X only)
Terminals  2.5mm2(12 AWG)
Mounting  T-section DIN-rail 35 x 7.5 or 35 x 15mm rail(1.38” x 0.3” x 0.6”)
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Weight 70g approximately (2.5oz)
Case flammability  UL94 V-2
AC durability   1Arms, 5T
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Service conditions
80kPa - 160kPa
5% - 95% RH
EMC compliance
To Generic Immunity Standards,
EN 61326-1, part 2 for industrial
environments
R&TTE compliance
EN 61326-1, EN 41003 : 1999
EN 60950 - 1 : 2006
(not applicable to SD150X and SD275X)
LVD compliance
SD150X & SD275X
EN 60950 - 1 : 2006, EN 61010 : 2010
SDPST
EN 41003 : 1999
IEC compliance
EN 61643-21:2001
ANSI/IEEE testing
C62.41-1-2002
C62.41-2-2002
C62.45-2002


 
Similar Models of MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
IOP32D  IOP32  IOP-AC   IOP HC32   SD16MDX-BDG SD07M  SD16M SD32M  SD55M SD32M-HC
SD07 SD16 SD32 SD55 SD07R SD16R SD32R SD55R SD07X SD16X SD32X SD55X SD32T3 SD07R3 SD16R3 SD32R3 SD55R3 SDRTD SDPSTN SLP07D SLP16D SLP32D SD32T3, SDRTD, SDR3 MA15/D/1/SI MA15/D/2/SI MA15/D/1TT/SI MA15/D/2TT/L MA30/D/1/SI MA30/D/2/SI MA30/D/3/SI MA05/D/1 MA05/D/2 MA10/D/1 MA10/D/2 MA05/SC/1 MA05/SC/2 MA10/SC/1 MA10/SC/2 MA05/I/1 MA05/I/2 MA10/I/1 MA10/I/2

 
Ording Models of MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
TP48-N Non-certified SPD - 1/2” NPT thread
TP48-I Non-certified SPD - 20mm ISO thread
TP48-G Non-certified SPD - G 1/2” (BSP 1/2 inch)
TP48-3-N Non-certified SPD - 1/2” NPT thread
TP48-3-I Non-certified SPD - 20mm ISO thread
TP48-3-G Non-certified SPD - G 1/2” BSP 1/2 inch
TP48-4-N Non-certified SPD - 1/2” NPT thread
TP48-4-I Non-certified SPD - 20mm ISO thread
TP48-4-G Non-certified SPD - G 1/2” BSP 1/2 inch
TP48-N-NDI Certified SPD - 1/2” NPT thread
TP48-I-NDI Certified SPD - 20mm ISO thread
TP48-G-NDI Certified SPD - G 1/2” (BSP 1/2 inch)
TP48-3-N-NDI Certified SPD - 1/2” NPT thread
TP48-3-I-NDI Certified SPD - 20mm ISO thread
TP48-3-G-NDI Certified SPD - 20mm ISO thread
TP48-4-N-NDI Certified SPD - 1/2” NPT thread
TP48-4-I-NDI Certified SPD - 20mm ISO thread
TP48-4-G-NDI Certified SPD - G 1/2” - BSP 1/2 inch
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
TP32-N      TP32-T-N 1/2” NPT thread
TP32-N-NDI  TP32-T-N-NDI 1/2” NPT thread, with EEx ia, EEx d, approval
TP32-I      TP32-T-I 20mm ISO thread
TP32-I-NDI  TP32-T-I-NDI 20mm ISO thread, with EEx ia, EEx d, approval
TP32-G      TP32-T-G G 1/2” (BSP 1/2 inch)
TP32-G-NDI  TP32-T-G-NDI G 1/2” (BSP 1/2 inch), with EEx ia, EEx d, approval
 

MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
TP24/7-N-NDI Certified process transmitter surge protection device - 1/2” NPT thread
TP24/7-I-NDI Certified process transmitter surge protection device - 20mm ISO thread
TP24/7-G-NDI Certified process transmitter surge protection device - G 1/2” (BSP 1/2”)
TP24/7-N Non-certified process transmitter surge protection device - 1/2” NPT thread
TP24/7-I Non-certified process transmitter surge protection device - 20mm ISO thread
TP24/7-G
TP24/7 All
TP24/7-X-NDI
TP24/7-T-XNDI
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
TP-ACFF-N AC power & Foundation Fieldbus 1/2” NPT Thread 
TP-ACFF-I AC power & Foundation Fieldbus 20mm ISO Thread
TP-AC420-N AC power & 4-20mA 1/2” NPT Thread 
TP-AC420-I AC power & 4-20mA 20mm ISO Thread
TP-AC485-N AC power & Profibus DP (RS485) 1/2” NPT Thread 
TP-AC485-I AC power & Profibus DP (RS485) 20mm ISO Thread

MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
TP-P32-N-NDI Certified process transmitter surge protection device - 1/2” NPT thread
TP-P32-I-NDI Certified process transmitter surge protection device - 20mm ISO thread
TP-P32-G-NDI Certified process transmitter surge protection device - G 1/2” (BSP 1/2")
TP-P32-N Non-certified process transmitter surge protection device - 1/2” NPT thread
TP-P32-I Non-certified process transmitter surge protection device - 20mm ISO thread
TP-P32-G Non-certified process transmitter surge protection device - G 1/2” (BSP 1/2")

MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
TP-P48-N-NDI Certified process transmitter surge protection device - 1/2” NPT thread
TP-P48-I-NDI Certified process transmitter surge protection device - 20mm ISO thread
TP-P48-G-NDI Certified process transmitter surge protection device - G 1/2” (BSP 1/2")
TP-P48-N Non-certified process transmitter surge protection device - 1/2” NPT thread
TP-P48-I Non-certified process transmitter surge protection device - 20mm ISO thread
TP-P48-G Non-certified process transmitter surge protection device - G 1/2” (BSP 1/2")
TS10-P 10 pair protection for PSTN applications
TS10-I 10 pair protection for ISDN or private wire applications
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Transmitters
MTL831B Analogue transmitter
 
Receivers
MTL838B-MBF Analogue receiver, RS485 and/or RS422 outputs for Modbus®
 
Analogue receiver accessories
PCS83 PC software configuration package
 
Process controller interface software
Contact Eaton's MTL product line for details of software for interfacing with proprietary process controllers
 
Isolating interface units and earth leakage detectors
MTL3052 Digital isolator interface unit
MTL4220 Earth leakage detector


MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Enclosures
ENC8 General-purpose enclosure
ENC8SS General-purpose enclosure (stainless steel)
ENC83 Enclosure for MTL831B transmitter
ENC83SS Enclosure for MTL831B transmitter (stainless steel)
 
Literature
INM838B-MBF System protocol manual:
MTL838B-MBF Modbus® receivers
INM831B MTL831B manual
AN9010 Application Note: A user's guide to intrinsically safe input multiplexer systems
INS831B MTL831B mV Multiplexer transmitter
INS838B MTL838B-MBF Multiplexer receiver - Modbus® output


MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
 
Mounting accessories
ISP7000 Insulating spacer
THR2 Standard DIN rail, 35mm x 7.5mm
THR7000 T-section DIN rail, specially nickel plated,
35mm x 7.5mm, 1m length
 
Earthing/earth rail accessories
ETL7000 Earth terminal, DIN rail mounted
IMB57 Insulated mounting block (two needed)
ERB57S Earth rail bracket, straight
ERB57O Earth rail bracket, offset
ERL7 Earth rail, 1m length
ETM7 Earth terminal, pack of 50

MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
Tagging accessories
TAG57 Tagging strip, 1m length
TGL57 Tagging strip labels, set of 10 x 0.5m
BRI7000 Barrier identifier
BIL7000 Barrier identification labels, sheet of 120
BIL7000L Barrier identification labels, A4 sheet of 126
 
Enclosures
DX070 Enclosure for up to 9 x SD range SPDs
DX170 Enclosure for up to 22 x SD range SPDs
 
Accessories (replacement)
SD-F25 Replaceable fuse pack - 250mA standard(available in packs of 5)
RFA7050 Replaceable fuse pack - 50mA special(available in packs of 5)
RLA7000 Solid Link (available in packs of 5)
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
MTL4113P Failsafe Proximity Detector input with LFD Baseefa certification to IEC61508 pending
MTL5113P Failsafe Proximity Detector input with LFD Baseefa certification to IEC61508 pending
MTL4043 Current Repeater - Current sinking Eutech assessed to IEC61508
(smart transmitters)
MTL4041B-SR Current Repeater (smart transmitters) BASEEFA certified to IEC61508
MTL4041P-SR Current Repeater - high power BASEEFA certified to IEC61508(smart transmitters)
MTL4024-SR Solenoid / alarm driver BASEEFA certified to IEC61508
MTL4061-SR Fire & Smoke detector interface BASEEFA certified to IEC61508
MTL5021-SR Solenoid / alarm driver BASEEFA certified to IEC61508
MTL5022-SR Solenoid / alarm driver IIB gases BASEEFA certified to IEC61508
MTL5025-SR Solenoid / alarm driver low power BASEEFA certified to IEC61508
MTL5042-SR Current Repeater (smart transmitters) BASEEFA certified to IEC61508
MTL5061-SR Fire & Smoke detector interface BASEEFA certified to IEC61508
MTL4841/2 HART Multiplexers BASEEFA certified to IEC61508
E02011 Current Repeater Assessment to DIN 19250
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
MLDT28500 MTL data surge tester
MTL4024-SR
MTL4041B-SR
MTL4041P-SR
MTL4061-SR
MTL5021-SR
MTL5022-SR
MTL5025-SR
MTL5042-SR
MTL5061-SR
MTL4841/2 
 
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
TP48-N TP48-N-NDI TP48-I TP48-I-NDI TP48-G TP48-G-NDI TP48-3-N-NDI TP48-3-I-NDI TP48-3-G-NDI TP48-3-N TP48-3-I TP48-3-G TP48-4
-N-NDI TP48-4-I-NDI TP48-4-G-NDI TP48-4-N TP48-4-I TP48-4-G ICC201-I1-O1 ICC201-I1-O2 ICC201-I2-O1 ICC201-I2-O2 ICC201-I2-O2  
ICC211-I1-O2 ICC211-I2-O1 ICC211-I2-O2 ICC212 ICC221 ICC222 ICC241-T3 ICC241-T1 ICC241-T2 ICC301-I9-O1 ICC312 ICC316-T2 ICC317
-T2-LFD ICC352-T1 ICC352-T2 ICC441 ICC446
 
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
MTL4501-SR, MTL4504, MTL4510, MTL4510B, MTL4511, MTL4513, MTL4514 (B)(D), MTL4516, MTL4516C, MTL4517, MTL4521, MTL4521L, 
MTL4523, MTL4523L, MTL4523R, MTL4523V, MTL4523VL, MTL4524, MTL4524S, MTL4525, MTL4526, MTL4531, MTL4532, MTL4533, MTL4541, 
MTL4541A, MTL4541AS, MTL4541B, MTL4541P, MTL4541S, MTL4541T, MTL4544, MTL4544A, MTL4544AS, MTL4544B, MTL4544D, MTL4544S, 
MTL4546, MTL4546C, MTL4546S, MTL4546Y, MTL4549, MTL4549C, MTL4549Y, MTL4561, MTL4575, MTL4576-RTD, MTL4576-THC, MTL4581
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
MTL5501-SR, MTL5510, MTL5510B, MTL5511, MTL5513, MTL5514, MTL5514D, MTL5516C, MTL5517, MTL5521, MTL5522, MTL5523, MTL5523V, 
MTL5523VL, MTL5524, MTL5525, MTL5526, MTL5531, MTL5532, MTL5533, MTL5541, MTL5541A, MTL5541AS, MTL5541S, MTL5544, MTL5544A, 
MTL5544AS, MTL5544D, MTL5544S, MTL5546, MTL5546Y, MTL5549, MTL5549Y, MTL5561, MTL5575, MTL5576-RTD, MTL5576-THC, MTL5581, 
MTL5582 MTL5544D MTL5575 MTL5516C MTL4541 MTL5541 MTL5546Y ICC212 IOP32 IOP32D
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
MTL7706+ MTL7707+ MTL7707P+ MTL7710+ MTL7715+ MTL7715P+ MTL7722+ MTL7728+ MTL7728- MTL7728AC MTL7728P+ MTL7729P+ MTL7741 
MTL7742 MTL7743 MTL7744 MTL7745 MTL7755AC MTL7756AC MTL7758- MTL7758+ MTL7760AC MTL7761AC MTL7761PAC MTL7764+ MTL7764AC 
MTL7765AC MTL7766AC MTL7766PAC MTL7767+ MTL7778AC MTL7779+ MTL7787+ MTL7787- MTL7787P+ MTL7788+ MTL7788R+ MTL7789+ MTL7796- MTL7796+ MTL7798 MTL7799 MTL705+ MTL706+ MTL707+ MTL707P+ MTL708+ MTL710+ MTL710AC MTL710P+ MTL715+ MTL715P+ MTL722+ MTL722P+ MTL728+ MTL728AC MTL728P+ MTL729P+ MTL751AC MTL755AC MTL758+ MTL760AC MTL761AC MTL761PAC MTL764+ MTL764AC MTL765AC MTL766AC MTL766PAC MTL767+ MTL768+ MTL772AC MTL778AC MTL779+ MTL786+ MTL787+ MTL787S+ MTL787SP+ MTL788+ MTL788R+ MTL791 MTL796+ MTL799
 
ICC     MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
ICC201-I1-O1 ICC201-I1-O2 ICC201-I2-O1 ICC201-I2-O2 ICC201-I2-O2 ICC211-I1-O2 ICC211-I2-O1 ICC211-I2-O2 ICC212 ICC221
 ICC222 ICC241-T3 ICC241-T1 ICC241-T2 ICC301-I9-O1 ICC312 ICC316-T2 ICC317-T2-LFD ICC352-T1 ICC352-T2 ICC441 ICC446
 
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
MTL4510 MTL4510B MTL4511 MTL4513 MTL4514 MTL4514B MTL4514D MTL4516 MTL4516C MTL4517 MTL4521 MTL4521L MTL4523 MTL4524R MTL4523L MTL4524 MTL4524S MTL4524 MTL4526 MTL4531 MTL4532 MTL4541 MTL4541A MTL4541B MTL4544 MTL4544A MTL4544D MTL4544S MTL4546Y MTL4549 MTL4549Y MTL4546 MTL4573 MTL4575 MTL4576-RTD MTL4576-THC MTL4581 MTL4599 MTL4599N
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
MTL5510 MTL5510B MTL5511 MTL5513 MTL5514 MTL5514D MTL5516C MTL5517 MTL5521 MTL5522 MTL5523 MTL5523V MTL5523VL MTL5524 MTL5525 MTL5526 MTL5531 MTL5532 MTL5533 MTL5541 MTL5541AS MTL5541S MTL5544 MTL5544A MTL5544AS MTL5544D MTL5544S MTL5546 MTL5546Y MTL5549 MTL5549Y MTL5561 MTL5573 MTL5575 MTL5576-RTD MTL5576-THC MTL5581 MTL5582 MTL5599 MTL5314 MTL5501-SR MTL5510 MTL5510B MTL5511 MTL5513 MTL5514 MTL5516C MTL5517 MTL5521 MTL5522 MTL5523 MTL5524 MTL5525 MTL5526 MTL5531 MTL5532 MTL5533 MTL5541 MTL5541A MTL5541AS MTL5541S MTL5544 MTL5544A MTL5544AS MTL5544D MTL5544S
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
MTL4501-SR MTL4504 MTL4510 MTL4510B MTL4511 MTL4513 MTL4514 MTL4516 MTL4516C MTL4517 MTL4521 MTL4521L MTL4523 MTL4523R MTL4523L MTL4524 MTL4524S MTL4525 MTL4526 MTL4531 MTL4532 MTL4533 MTL4541 MTL4541A MTL4541AS MTL4541B MTL4541P MTL4541S MTL4544 MTL4544A MTL4544AS MTL4544B MTL4544D MTL4544S MTL4546 MTL4546C MTL4546Y MTL4549 MTL4549C MTL4549Y MTL4561 MTL4575 MTL4576-RTD MTL4576-THC MTL4599 MTL4599N
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
MTL7706+ MTL7707+ MTL7707P+ MTL7710+ MTL7715+ MTL7715P+ MTL7722+ MTL7728+ MTL7728- MTL7728AC MTL7728P+ MTL7729P+ MTL7741 
MTL7742 MTL7743 MTL7744 MTL7745 MTL7755AC MTL7756AC MTL7758- MTL7758+ MTL7760AC MTL7761AC MTL7761PAC MTL7764+ MTL7764AC 
MTL7765AC MTL7766AC MTL7766PAC MTL7767+ MTL7778AC MTL7779+ MTL7787+ MTL7787- MTL7787P+ MTL7788+ MTL7788R+ MTL7789+ MTL7796- MTL7796+ MTL7798 MTL7799 
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
MTL705+ MTL706+ MTL707+ MTL707P+ MTL708+ MTL710+ MTL710AC MTL710P+ MTL715+ MTL715P+ MTL722+ MTL722P+ MTL728+ MTL728AC MTL728P+ MTL729P+ MTL751AC MTL755AC MTL758+ MTL760AC MTL761AC MTL761PAC MTL764+ MTL764AC MTL765AC MTL766AC MTL766PAC MTL767+ MTL768+ MTL772AC MTL778AC MTL779+ MTL786+ MTL787+ MTL787S+ MTL787SP+ MTL788+ MTL788R+ MTL791 MTL796+ MTL799
 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived
 
HAZ1-3 HAZ4-6 SAF1-3 SAF4-6 SAF7-9 SAF10-12 PWR5000 HAZ-CJC TAG57 TGL57 PB-8T PB-16T PB-24T PB-32T IMB57 MLTHR2 ERB57S ERB57O 
ERL7 MLETM7 MS010 TH5000 PCS45 PCL45USB DX070 DX170 BMK08 BMK16 DMK01 DMP08 DVK16 MCC45 MCK45 SCK45 MPL01 PCL45USB PCS45 CPM08 CPM16U CPM32U CPS04 CGS08 CPS08 CPS16 CPS16C-250 CPS24 CPS16C BPS04 BPS08 ERK04 ERK06 ERK08 ERK16 HMP24 SVK16 TSK08 TSK16 TSK24

 
MTL SD16R3 Surge Protection Devices SD16R3 Surge Protectors Arrived



We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers,Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.
 
 
We mainly supply Yokogawa,Emerson, Rosemount,Fisher,Honeywell,Siemens, ABB,FLUKE, Schneider Electric, Pepperl+Fuchs,MTL,Rockwell(Allen Bradley), Hirschmann, Eaton ,Moeller,FUJI,Omron, Yaskawa,Norgren,CHINT,Hach,Weidmuller,Phoenix, SMC,Testo, ASCO,Parker,Mitsubishi, Festo,GE, CISCO,Auma,IFM,GM,Turck,MOXA, Foxboro, Krohne, Swagelok, LS, Advantech, Dwyer,Endress Hauser, Bently Nevada,Moog etc.
 
 
Contact:
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)
 
Previous:MTL SD55R Surge Protection Devices SD55R Surge Protectors Ar Next:MTL SD32R3 Surge Protection Devices SD32R3 Surge Protectors
 Footer begin -->